製品: GUCY2C Antibody
カタログ: DF13895
タンパク質の説明: Rabbit polyclonal antibody to GUCY2C
アプリケーション: IHC
反応性: Human, Mouse, Rat
分子量: 120~150kD; 123kD(Calculated).
ユニプロット: P25092

類似製品を見る>>

   サイズ 価格 在庫状況
 100ul $280 在庫あり
 200ul $350 在庫あり

リードタイム: 当日配達

For pricing and ordering contact:
お問い合わせ先

製品説明

ソース:
Rabbit
アプリケーション:
IHC 1:50-1:200
*The optimal dilutions should be determined by the end user.
*Tips:

WB: For western blot detection of denatured protein samples. IHC: For immunohistochemical detection of paraffin sections (IHC-p) or frozen sections (IHC-f) of tissue samples. IF/ICC: For immunofluorescence detection of cell samples. ELISA(peptide): For ELISA detection of antigenic peptide.

反応性:
Human,Mouse,Rat
クローナリティ:
Polyclonal
特異性:
GUCY2C Antibody detects endogenous levels of total GUCY2C.
コンジュゲート:
Unconjugated.
精製:
The antiserum was purified by peptide affinity chromatography using SulfoLink™ Coupling Resin (Thermo Fisher Scientific).
保存:
Rabbit IgG in phosphate buffered saline , pH 7.4, 150mM NaCl, 0.02% sodium azide and 50% glycerol. Store at -20 °C. Stable for 12 months from date of receipt.
別名:

折りたたみ/展開

GC-C; Guanylyl cyclase C; GUC2C; GUC2C_HUMAN; GUCY2C; Heat stable enterotoxin receptor; Heat-stable enterotoxin receptor; hSTAR; Intestinal guanylate cyclase; STA receptor;

免疫原

免疫原:

A synthesized peptide derived from Human GUCY2C.

Uniprot:
遺伝子(ID):
タンパク質配列:
MKTLLLDLALWSLLFQPGWLSFSSQVSQNCHNGSYEISVLMMGNSAFAEPLKNLEDAVNEGLEIVRGRLQNAGLNVTVNATFMYSDGLIHNSGDCRSSTCEGLDLLRKISNAQRMGCVLIGPSCTYSTFQMYLDTELSYPMISAGSFGLSCDYKETLTRLMSPARKLMYFLVNFWKTNDLPFKTYSWSTSYVYKNGTETEDCFWYLNALEASVSYFSHELGFKVVLRQDKEFQDILMDHNRKSNVIIMCGGPEFLYKLKGDRAVAEDIVIILVDLFNDQYFEDNVTAPDYMKNVLVLTLSPGNSLLNSSFSRNLSPTKRDFALAYLNGILLFGHMLKIFLENGENITTPKFAHAFRNLTFEGYDGPVTLDDWGDVDSTMVLLYTSVDTKKYKVLLTYDTHVNKTYPVDMSPTFTWKNSKLPNDITGRGPQILMIAVFTLTGAVVLLLLVALLMLRKYRKDYELRQKKWSHIPPENIFPLETNETNHVSLKIDDDKRRDTIQRLRQCKYDKKRVILKDLKHNDGNFTEKQKIELNKLLQIDYYNLTKFYGTVKLDTMIFGVIEYCERGSLREVLNDTISYPDGTFMDWEFKISVLYDIAKGMSYLHSSKTEVHGRLKSTNCVVDSRMVVKITDFGCNSILPPKKDLWTAPEHLRQANISQKGDVYSYGIIAQEIILRKETFYTLSCRDRNEKIFRVENSNGMKPFRPDLFLETAEEKELEVYLLVKNCWEEDPEKRPDFKKIETTLAKIFGLFHDQKNESYMDTLIRRLQLYSRNLEHLVEERTQLYKAERDRADRLNFMLLPRLVVKSLKEKGFVEPELYEEVTIYFSDIVGFTTICKYSTPMEVVDMLNDIYKSFDHIVDHHDVYKVETIGDAYMVASGLPKRNGNRHAIDIAKMALEILSFMGTFELEHLPGLPIWIRIGVHSGPCAAGVVGIKMPRYCLFGDTVNTASRMESTGLPLRIHVSGSTIAILKRTECQFLYEVRGETYLKGRGNETTYWLTGMKDQKFNLPTPPTVENQQRLQAEFSDMIANSLQKRQAAGIRSQKPRRVASYKKGTLEYLQLNTTDKESTYF

研究背景

機能:

Receptor for the E.coli heat-stable enterotoxin (E.coli enterotoxin markedly stimulates the accumulation of cGMP in mammalian cells expressing GC-C). Also activated by the endogenous peptides guanylin and uroguanylin.

PTMs:

Glycosylation at Asn-75 and/or Asn-79 is required for interaction with VIP36 while glycosylation at Asn-345 and Asn-402 modulates ligand-mediated GC-C activation.

細胞の位置付け:

Cell membrane>Single-pass type I membrane protein. Endoplasmic reticulum membrane>Single-pass type I membrane protein.
Note: The 145 kDa plasma membrane form of GC-C contains sialic acid and galactose residues, while a differencially glycosylated 130 Kda form is a high mannose form that is resident in the endoplasmic reticulum and may serve as the precursor for the cell surface form.

Extracellular region or secreted Cytosol Plasma membrane Cytoskeleton Lysosome Endosome Peroxisome ER Golgi apparatus Nucleus Mitochondrion Manual annotation Automatic computational assertionSubcellular location
サブユニット構造:

Homotrimer. Interacts via its C-terminal region with PDZK2. Interacts with the lectin chaperone VIP36.

タンパク質ファミリー:

The protein kinase domain is predicted to be catalytically inactive.

Belongs to the adenylyl cyclase class-4/guanylyl cyclase family.

研究領域

· Metabolism > Nucleotide metabolism > Purine metabolism.

Restrictive clause

 

Affinity Biosciences tests all products strictly. Citations are provided as a resource for additional applications that have not been validated by Affinity Biosciences. Please choose the appropriate format for each application and consult Materials and Methods sections for additional details about the use of any product in these publications.

For Research Use Only.
Not for use in diagnostic or therapeutic procedures. Not for resale. Not for distribution without written consent. Affinity Biosciences will not be held responsible for patent infringement or other violations that may occur with the use of our products. Affinity Biosciences, Affinity Biosciences Logo and all other trademarks are the property of Affinity Biosciences LTD.